Gravity Grease Interceptor (All Sizes) Proceptor Single Manway Fiberglass Gravity Grease Interceptors are engineered to deliver market leading separation and capture wastewater grease, food solids and sediment. The patented fiberglass design is simple to clean and maintain, and is backed Read More. Specs and Installation. Where To Buy.
Learn MoreFormula Explanations Grease Trap Sizing (Hydro Mechanical) 2 or 3 Compartment sink Cubic Capacity = width x length x depth (in inches) Volume in Gallons = Cubic Capacity / 231 1 US Gallon = 231 cubic inches (volume) Remember: Hydro Mechanical Interceptors are Measured By FLOW (GPM) Grease Interceptor Sizing (Gravity)
Learn MoreZurn offers a full line of Oil and Solids Interceptors designed specifically for the auto industry with sizes up to 10,000 gallons. Traps & Primers. Stainless Drains. Light Commercial. Trench Drain Systems. Acid Neutralization. Liquid Volume Sizing (U.S. G/L) 50 (189)
Learn MoreA grease trap is a small FOG removal unit designed for use in kitchen applications where the flow of water and amount of oil and grease produced
Learn More1/17 · For restaurants, the sizing formula is: Formula 2. Grease Interceptor Liquid Capacity, U.S. EPA Method. 6 Where D = Number of seats in dining area GL = Gallons of wastewater per meal, normally 5 gallons ST = Storage capacity factor – minimum of 1.7, on-site disposal, 2.5 HR = Number of hours open LF = Loading factor 1.25 – interstate freeways
Learn MoreGrease Interceptor: 4 in Pipe Dia., 100 gpm Flow Rate, 180 lb Capacity, Polyethylene ; Overall Height 54 in ; Overall Width 31 in ; Overall Depth 66 in ; Max. Temp.
Learn MoreProceptor GMC UPC Gravity Grease Interceptor - 2 Manway (All Sizes) Specs and Installation Where to buy Proceptor GMC 100-500 Proceptor GMC 100-500 Fiberglass Hydromechanical
Learn MoreGrease Interceptor The Z1170 Grease Interceptor is an acid resistant coated interior and exterior fabricated steel grease interceptor, PDI Rated, with internal air relief by-pass. This interceptor
Learn Morecannot be specified when the aluminum cover is used. –BB Timer Battery Backup(For Z1174) –C30 Cable Length of 30 Feet For Digital Display(For Z1192) –C45 Cable Length of 45 Feet
Learn MoreTable 4 on the next page (“HGI Sizing Chart”) is used to determine the size of HGI needed, if that is the type of grease interceptor being installed. In Example 1, based on 29 DFUs a 75 gallon per minute (gpm) unit would be required. In Example 2, a 50 gpm unit would be required.
Learn MoreThe slip-resistant cover of this grease trap is secured with a center tie down assembly to prevent odors from escaping. The grease trap comes equipped with complete inlet and outlet connections with no-hub threads. The grease trap has a grease capacity of 8 lb. and a 4 GPM flow rate. Overall Dimensions: Length: 16 3/8". Width: 9 7/8". Height: 10".
Learn MoreProceptor GMC Gravity Grease Interceptor (All Sizes) Proceptor Single Manway Fiberglass Gravity Grease Interceptors are engineered to deliver market leading separation and capture wastewater grease, food solids and sediment. The patented fiberglass design is simple to clean and maintain, and is backed Read More Specs and Installation
Learn MoreFats, Oils and Grease are also known as FOG, which comes from food such as cooking oil, lard, shortening, meat fats, sauces, gravy, mayonnaise, butter, ice cream and soups. Sink, dishwasher, hood and floor cleaning wastewaters and food scraps may also be sources of FOG. FOG can either be liquid or solid and may turn viscous or solid as it cools
Learn MoreGrease traps must have the NSF or Plum Drainage Institute certification. The minimum acceptable size is rated at 20 gpm / 40lbs. All grease traps must be
Learn MoreSizing a Grease Trap or Interceptor · You'll need to measure the fixture's length, width, and height to determine the fixture's capacity in cubic inches (LxWxH).
Learn Moresize and promoting decay, leading to unpleasant odor and unsanitary conditions. Under these conditions, pipes can readily become clogged GREASE INTERCEPTORS ZURN PLUM PRODUCTS GROUPSPECIFICATION DRAINAGE OPERATION, 1801 PITTSBURGH AVENUE, ERIE, PA 16502 PHONE 814/455-0921 FAX: 814/454-7929 WEBSITE: www.zurn.com
Learn MoreAdopted codes and standards. The division works with building officials, technical committees, advisory boards, and the public to adopt, amend, and interpret the Oregon Plum Specialty Code (OPSC). This code applies to the installation, alteration, repair, relocation, and replacement of plum systems in commercial and residential buildings.
Learn MoreBrand: Zurn 40# Grease Trap w/ 2" No Hub Inlet, 20gpm Product Image. Not Added to List Icon 50# Semi Auto Grease Trap w/ Drawoff Valve, 25 gpm (2".
Learn MoreGrease Interceptors Market - Global Outlook and Forecast 2022-2028. HTF3821190. Report Format PDF. Pages 75. Views
Learn MoreGrease Interceptors from Zurn's are CSA and PDI Certified. Our Grease, Oil and Solid Interceptors are high performing and come in different variants, the right fit for All of Your Separation Needs Liquid Volume Sizing (U.S. G/L) 50 (189) Grease Interceptor are manufactured with patented distributed flow pattern and corrosion resistant
Learn MoreZurn Z1170-600 Grease Interceptor ~* Need help? Please call us: 407-878-7058 or email at [email protected]. *~* Some product pages are under maintenance & do not reflect current pricing.*~ ~*Please contact us to get pricing, availability, & to order for product pages under maintenance.*~ About Us Contact Info Login
Learn More