The shaftwall assemblies were evaluated for sound transmission loss values. These values are only valid if the assemblies are constructed as noted in the test reports. When the assemblies are installed in the same manner as noted in the test reports, the assembly will have a minimum STC (Sound Transmission Class) rating of 50. 3.
Learn MoreGold Bond® Shaftliners offer an efficient installation from the ground USG provides resources here for our UL wall assemblies for
Learn MoreThis 2-hour horizontal shaftwall assembly consists of 4” shaftwall studs with shaftliner panels between each stud and three layers of 5/8” Type
Learn MoreAssembly Shaftwalls, Stairwalls & Corridors Assemblies Evaluated For 1. Transverse Load Capacity 2. Fire Resistance 3. Sound Control Component Descriptions ClarkDietrich® Shaftwall & Stairwall non-load bearing assemblies consist of the following components: 1. J-Tabbed Track / J-Runners (Part No's. TTE2, TTE4, TTE6, TTN2, TTN4) 2. Steel C-T
Learn MoreUp to 4 Hours Fire Resistance. • UL Listed. • Tested with Major Elevator Door Frames. GYPSUM SHAFT WALL SYSTEMS. Fire Rated Assembly
Learn More22/11/ · This is a c.1920 building (Type III), full dimension 2X14 joists with 3/4 T&G flooring, overlayed with 1/2 ULF. Non-sprinklered building. The scope of the project is a change of use and complete renovation of the main floor A-3 to an A-2 (Restaurant / Bar). Designer has used the performance approach. There is a required 2-hour separation
Learn MoreUSG Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft UL listing for fire damper installation.
Learn MoreRoof-Ceiling Assemblies; Design Details; Shaft Wall Limiting Heights & Spans; Competitor Comparison Tool; USG Sustainability Tool; UL Type Designations; Frequently Asked Questions; Wall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details;
Learn MoreFind resources and details for UL rated wall systems with the required STC and fire ratings for your project. Products Products > Pipe Insulation. Batts. Pipe and Tank . Blown-in Insulation. Board. UL Wall Assemblies BIM - Revit Library Transparency Catalog > NAIMA 3E Plus FAQs Technical Support
Learn MoreSeveral options for 1- and 2-hour fire resistance-rated, wood-frame wall assemblies that could be useful for shafts are presented below. 1-Hour Single Wall UL U305 GA WP 3510 UL U311 IBC Table 721.1 (2), Item 14-1.3 UL U332 1-Hour Double Wall UL U341 2-Hour Single wall UL U301 UL U334 IBC Table 721.1 (2) Item Number 14-1.5
Learn MorePricing for installing 2-hour vertical and horizontal shaft wall assemblies was obtained from three contractors and averaged. Provides 2-hour fire rated
Learn MoreUSG Cavity Shaft Wall can be used in elevator and mechanical shafts, air ducts, stairwells, and areas where wall construction is only available from one side. In addition, USG Cavity Shaft Wall can be used to provide horizontal protection for corridor ceilings, underside of stairwells, and other applications. Is the Horizontal Shaft Wall UL tested?
Learn MoreGypsum Shaftwall™ Systems have replaced traditional masonry for interior From a cost standpoint, ProRoc® Shaftliner assemblies UL DESIGN U417.
Learn MoreThis 2-hour horizontal shaftwall assembly consists of 4" shaftwall studs with shaftliner panels between each stud and three layers of 5/8" Type C gypsum board applied to the underside of the framing. UL design G586 can span 8'-0" from wall to wall or indefinitely when used in conjunction with the hanger assembly.
Learn MoreUL U415 System B — Shaft Wall, Steel Stud (Non-Load-Bearing) Products Products > Pipe Insulation. Batts. Pipe and Tank . Blown-in Insulation. Board. Rolls. Elevated Temperature . UL Assemblies / Wall / UL U415 System B . UL U415 System B Shaft Wall, Steel Stud (Non-Load-Bearing) Stc 37; Fire Rating 2 Hour; System Thickness 3-3/4"
Learn More02/12/ · The area separation wall consists of two layers of 1 in. thick gypsum liner boards, secured through the use of floor, ceiling and intermediate horizontal C channels, and vertical H
Learn More01/07/ · each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. zOnly products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U497
Learn MoreDiscover Monokote products, UL Designs & Thickness and more about floor assemblies. Get started. Skip to main navigation menu Close. Products & Solutions. Air Barriers & Flashing. Overview; PERM-A-BARRIER® PERM-A-BARRIER® NPS; PERM-A-BARRIER® VPL 50RS UV Stable 4-1/2" NWC 2HR only, Fluted: UL D985: PDF: NA:.
Learn MoreThis is true fo r walls separating shafts when there is only a structural beam provided for supporting the wall.Shaft Wall Ceiling Membrane The two-hour horizontal membrane (also used in two-hour duct enclosures), and the membranes used as the ceiling of one- and two-hour egress corridors, are shown on page 23.2hr horizontal shaft wall assembly ul.Get Toyota Corolla
Learn More2HR SHAFTWALL PARTITION -. SEE FLOOR PLAN AND DESIGN AND APPLICABLE U.L. DESIGN NUMBERS. FIRESTOP SYSTEM ASSEMBLY;. UL DESIGN #K506.
Learn More01/01/ · This assembly, ULC W446, System J, specifies three hours of fire resistance. Its illustration in Figure 6 shows three layers of 16-mm Type X gypsum board—two layers on the corridor side, one layer on the shaft side. Horizontal shaftwall design A horizontal shaftwall is designed in response to two different needs.