UL Wall Assemblies. Find and download resources for STC rated wall assemblies for your construction project. Revit, CAD, and construction details for fire
Learn MoreCGC Shaft Wall Systems are non-load-bearing gypsum wall partition assemblies constructed from outside the shaft at each floor. Shafts are enclosed early in construction, and the walls are finished later, along with interior partitions. Installation is quick and easy, using components and application procedures familiar to drywall contractors.
Learn MoreUSG's range of resources on UL wall assemblies can help with the planning and Shaft Wall - Steel Stud (Non-Load-Bearing). Fire Rating. 1 hours.
Learn MoreThe Cavity Shaft Wall System includes components that provide the strength to withstand lateral loads and fire protection necessary for walls that enclose elevator shafts, stairwells and other vertical shafts. The system includes gypsum liner panels, gypsum panels and cement board, interior finishing products and framing components. Main Features
Learn MoreUSG's range of resources on UL wall assemblies can help with the planning and estimation of Chase Wall - Wood Stud (Load-Bearing). Fire Rating. 1 hours.
Learn More6/23 · UL design G586 can span 8’-0” from wall to wall or indefinitely when used in conjunction with the hanger assembly. For 1-hour assemblies, National Gypsum developed UL design I504, which is a 1-hour horizontal assembly that consists of 3-5/8” steel studs 16” o.c. with three layers of 5/8” Type X gypsum board applied to the underside of the framing.
Learn MoreSecond, choose the type of design you are seeking (example – Walls/Partitions (steel framed), Floor/Ceiling (wood framed), etc.) Or search by the assembly number (UL design, or Gypsum Association file number) Then click on the Search button, and your results will be displayed below. 1-800-545-6302 ext. 5607 [email protected]
Learn MoreFor Fire Resistance details and construction methods, refer to UL Design #U415 System A and the USG installation instructions. Two-Hour Cavity Shaft Wall (Non-
Learn MoreUL U415 System B Shaft Wall, Steel Stud (Non-Load-Bearing) Stc 37 Fire Rating 2 Hour System Thickness 3-3/4" PDF (276.2 KB PDF) REVIT (1.99 MB RVT) CAD (66.60 KB DWG) Assembly Details Gypsum Board 1" thick Thick Gypsum Liner Panel (UL Type SLX) Steel Studs 2-1/2" thick CH Studs, 20ga. MSG., Spaced 24" O.C. Gypsum Board
Learn MoreAssembly Details Gypsum Board 1" [25.4 mm] Sheetrock ® Gypsum Liner Panels (UL Type SLX) Steel Studs 2-1/2" [64 mm] CH studs, 20 ga. (0.033"), 24" [610 mm] O.C. Insulation 2-1/2" [64 mm] Knauf EcoBatt Insulation Gypsum Board 3 layers of 5/8" [15.9 mm] Sheetrock ® EcoSmart Gypsum Panel (UL Type ULIX ™) Notes View assembly information on UL Website.
Learn More12/2 · The area separation wall consists of two layers of 1 in. thick gypsum liner boards, secured through the use of floor, ceiling and intermediate horizontal C channels, and vertical H
Learn MoreMeet exterior wall system requirements Exterior wall assemblies are designed to resist the impacts of fire, wind, rain, hail, extreme temperatures and sound, and be energy efficient, attractive and much more. We understand these challenges. We provide testing, inspection, and certification solutions for exterior wall assemblies.
Learn Moreand gypsum Shaftliner manufacturers are approved in several UL fire- rated assemblies for both 1 and 2-hour ratings . ASTM & Code Standards. • ICC-ESR 4934.
Learn MoreAttach 2" (51 mm) wide C-Track to slab at bottom of wall using suitable fasteners at a maximum of 24" (610 mm) o.c. Allow a 3/4" (19 mm) space from wood or steel stud framing on each side of the firewall. 2. Install vertical C-Track at the beginning of the wall and support as needed. 3.
Learn MoreDesign/System/Construction/Assembly Usage Disclaimer U499. April 26, 2010. Nonbearing Wall Rating — 1 Hr. 1. Channel Track — "J" -shaped
Learn More4/26 · Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U499 April 26, Nonbearing Wall Rating — 1 Hr. 1. Channel Track — "J" -shaped channel, 2-1/2 in. deep with unequal legs of 1 in. and 2
Learn Moreinstallation from a single side—no need for scaffolding within the shaft, and a cost effective solution. PABCO Wall Assembly diagram of 2‐Hour Shaftwall System angles to studs with 1" Type S screws 24" o.c. UL Design U 429 allows use of 5/8" FLAME CURB® Type C, 4'
Learn MoreFire-Rated Assemblies 3 USG Shaft Wall Systems 09 20 00/USG BuyLine 2425 1 Hour Fire-rated Construction Non-loadbearing Acoustical Performance Construction Detail Description Test Number STC Test Number wt. 8 † 5/8 SHEETROCK® brand FIRECODE® Core gypsum UL
Learn MoreFire-Rated Wall Assemblies. LP® FlameBlock® Fire-Rated OSB Sheathing is a component of the following 1-Hour Exterior Wall Assembly - UL Design No. U348
Learn More7/12 · Just build a one hour wall against the exiting. Not sure if I will describe it correctly, but find a UL or other approved one hour listed design. Just start with half the rated wall against the existing wall, add the studs or built it on the ground and stand it, than add the other layer of sheet rock. Wella a one hour rated wall. C cda Sawhorse 123
Learn MoreWall Assemblies; Floor-Ceiling Assemblies; Roof-Ceiling Assemblies; Design Details; UL Type Designations; Frequently Asked Questions; Acoustical Ceilings Performance Substrate; Sealant Fire Tests; Material Estimators Material Estimators. Shaft Wall 1-Hr. AER-09038. More; Need Help?