disabled (see parameter A187). Mounting Considerations Frame Screw Size Screw Torque C M5 (#10-24) 2.45-2.94 N-m (22-26 lb.-in.) PowerFlex 400 Adjustable Frequency AC Drive Quick Start English-3 Minimum Mounting Clearances Figure 1: Frame C Mounting Clearances Figure 2: Frames D, E and F Mounting Clearances
Learn MoreReading (03) and Writing (06) Parameters. The Register address equals the Parameter number. For example, a decimal "1" is used for Parameter 1, a decimal
Learn MoreProgramming and Parameters This chapter provides a complete listing and description of the PowerFlex 400 parameters. Parameters are programmed (viewed/edited) using the integral keypad. As an alternative, programming can also be performed using DriveExecutive™ software or Connected Components WorkBench™ version 1.0
Learn Moreinformation, refer to the PowerFlex 400 User Manual, publication. 22C-UM001. Programming the Parameters for the Main Control Board on page 10.
Learn MoreOpen the project for your PowerFlex 400 drive. 3. On the main screen, click the Connect button to go online. 4. The firmware revision is displayed on the screen as shown below. Step Key(s) Example Display 1. Power up the drive. Then plug the HIM into the drive. The Parametersmenu for the drive is displayed. 2.
Learn MorePowerFlex 400 Adjustable Frequency AC Drives for Fan & Pump Applications Technical Data Certifications Meets or exceeds IEC 61800-9-2 IE2 energy efficiency requirements. CE Marked
Learn MoreAllen Bradley PowerFlex 40 Variable Frequency Drive Programming Parameters [d] Basic Display Parameters [P] Basic Program Group [A] Advanced Program Group. Basic Display Parameters: # Parameter; d001: Output Frequency: d002: Commanded Frequency: d003: Output Current: d004: Output Voltage: d005: DC Bus Voltage: d006: Drive Status: d007: Fault 1
Learn MoreAbout Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How works Test new features Press Copyright Contact us Creators
Learn MoreDigital increase/decrease speed control. • Parameter names are displayed as text. • Parameters are grouped into files based upon function, making programming
Learn MorePower ratings: 200240V: 0.37132 kW / 0.5200 Hp / 2.2477 A 380480V: 0.75250 kW / 1.0350 Hp / 2.1456 A 600V: 1.0300 Hp / 1.7289 A 690V: 7.5250 kW / 12263 A IP00/IP20 NEMA/UL Type Open, flange mount, IP54 NEMA/UL Type 12
Learn MorePowerFlex 753 AC Drives, PowerFlex 755 AC Drives, and PowerFlex 700 AC Drives About This Document This document applies to PowerFlex ® 753 , 755, and 700 AC Drives. Set P043 to 0 " Manual " to accommodate motor control because it looks less like an equivalent motor circuit to the drive.
Learn MoreSafety function: actuator subsystems - stop category 1, drives with safe torque-off (24 pages) Media Converter Allen-Bradley PowerFlex 525 Installation Instructions. Incremental encoder input (2 pages) Controller Allen-Bradley PowerFlex 527 Original Instructions Manual. Technical data, ac drive specifications (43 pages)
Learn MoreUser Manual since the October 2006 release. New Parameters. The following parameters have been added with the release of Firmware Release Number (FRN) 6.xx.
Learn MoreOverviewThe purpose of this manual is to provide you with the basic information needed to install, start-up and troubleshoot the PowerFlex 400 Adjustable Frequency AC Drive. Who Should Use This Manual? This manual is intended for qualified personnel. You must be able to program and operate Adjustable Frequency AC Drive devices.
Learn MoreChapter Programming and Parameters Chapter 3 provides a complete listing and description of the PowerFlex 400 parameters. Parameters are programmed (viewed/edited) using the
Learn MoreChapter Programming and Parameters Chapter 3 provides a complete listing and description of the PowerFlex 400 parameters. Parameters are programmed (viewed/edited) using the integral keypad. As an alternative, programming can also be performed using DriveExplorer™ or DriveExecutive™ software, a personal computer and a serial converter module.
Learn MoreThe PowerFlex 400 has a built-in PID (Proportional, Integral, Differential) control loop. The PID loop is used to maintain a process variable, such as pressure or flow, at a desired set point. The PID loop works by subtracting the PID feedback from a reference and generating an error value.
Learn MoreIncludes power ratings: 200240V: 0.3766 kW / 0.5100 Hp / 2.2260 A 380480V: 0.37132 kW / 0.5200 Hp / 1.1260 A 500600V: 1150 Hp / 1.7144 A 690V: 45132 kW / 52142 A Includes IP20 NEMA/UL Type 1, Open/Flange, IP54 NEMA 12 Provides V/Hz control, sensorless vector control, and vector control with FORCE™ Technology
Learn MorePowerFlex 400 Fault Codes If a FAULT has occurred, and you are at the TELEMETRY USER INTERFACE: 1. Note the FAULT CODE in the TELEMETRY USER INTEFACE 2. Address the condition that caused the FAULT. See Table Below For List of Fault Codes and Descriptions. The cause must be corrected before the fault can be cleared.
Learn MoreAvailable in power ratings of 3.0350 HP @ 480V AC and 3.050 HP @ 240V AC, the PowerFlex 400 is designed to meet global OEM, contractor and end-user demands for flexibility, space savings and ease-of-use. The PowerF lex 400 is a cost-effective solution for speed control in variable torque fan and pump applications. Product Overview Packaging
Learn More350HP @ 480VAC and 3.0-50HP @ 240V AC, the PowerFlex 400 is designed to meet global OEM, contractor and end-user demands for flexibility, space savings and ease-of-use. The PowerFlex 400 is a cost-effective solution for speed control in variable torque fan and pump applications. Table of Contents Description Page PowerFlex 400 Standard Product
Learn More